Skip to main content
Bashaer Al Khair — Water Leak Detection & Waterproofing
Active Service Coverage:Jeddah & Makkahالعربية
Bashaer Al Khair Waterproofing & Water Leak Detection
Bashaer Al KhairWaterproofing & Leak Detection
Hydrostatic Tank, Pool, Wet-Zone & Substructure EngineeringMakkah

Basement and Foundation Waterproofing in Makkah: Protecting Retaining Walls, Grade Beams and Basements

In Makkah, we waterproof footings, grade beams, rock-cut retaining walls and building basements. We guard against trapped groundwater in rock cracks and soil dampness. Protection boards go on before backfilling.

SBC 303 makes a clear difference between soil damp-proofing and waterproofing against groundwater pressure
Mandatory mechanical protection boards over membranes before soil backfilling
Solutions for both new foundations under construction and internal negative-side basement repair
Waterproofing engineer inspecting foundation wall and basement waterproofing membrane prior to backfilling in Jeddah and Makkah
Below-Ground Protection Based on Saudi Building Code SBC 303 (Soils and Foundations)Illustrative
Application Scope: Reinforced Concrete Footings, Grade Beams, Neck Columns, Retaining Walls and Basements (New and Existing) in Jeddah and Makkah
Engineering Problem Analysis in Makkah

Why Waterproofing Below Ground Is the First Defense for a Long-Lasting Building

Concrete below ground (footings, neck columns, grade beams, raft slabs and basement walls) is porous and soaks up soil moisture. Groundwater often carries dissolved chlorides and sulfates. In Jeddah and Makkah, salty groundwater can enter unprotected concrete. Sulfates attack the cement, and chlorides corrode the reinforcing steel. This causes cracks and spalling.

Unsealed grade beams and foundation necks also let soil moisture creep upward into ground-floor walls. This causes paint blistering and salt deposits above the skirting boards. In basements, unsealed retaining walls cause active seepage, flooded floors and mold.

01

Chronic Rising Damp, Salt Deposits and Peeling Paint Along Ground-Floor Walls

Technical Mechanism: Salty soil moisture wicks upward through unsealed foundation necks and grade beams into ground-floor blockwork.

Risk If Ignored:Interior ground-floor finishes and plaster keep failing, however often the walls are repainted.
02

Groundwater Seepage in Basement Retaining Walls, Floor Slabs or Elevator Pits

Technical Mechanism: Groundwater pressure from outside pushes water in through unsealed cold joints, tie-rod holes or outer membranes damaged during backfill.

Risk If Ignored:Flooded elevator pits, ruined basement interiors, and steady corrosion of retaining wall reinforcement.
03

Corrosion of Foundation Neck Rebar and Spalling of Underground Concrete Cover

Technical Mechanism: Applying a thin, diluted coat of cheap bitumen over rough, honeycombed concrete. There is no mortar smoothing and no protection boards before backfilling.

Risk If Ignored:Severe structural damage to load-bearing footings and columns, which later needs costly structural jacketing.
Substructure & Basement Waterproofing Diagram (SBC 303 Principles)

Protecting Footings, Grade Beams and Basements from Groundwater and Salts in Makkah

Tier 1: Footing & Grade Beam Damp-Proofing

For Footings, Neck Columns and Grade Beams Above the Water Table

Repairing honeycombs, trimming tie wires, and coating all buried faces and the top of grade beams (DPC) with rubberized bitumen. This blocks soil salts and rising damp.

Tier 2: Hydrostatic Basement & Pit Waterproofing

For Basements, Elevator Pits and Retaining Walls Under Water Pressure

Outer reinforced bitumen membrane tanking with waterstops and protection boards for new builds. For existing basements, inside crystalline waterproofing.

Illustrative diagram only. The actual layer order and spec are set after an on-site surface inspection, per manufacturer TDS.

Technical Service Definition & Scope Boundaries

Technical Definition & SBC 303 Principles for Substructure Protection

The Saudi Building Code for Soils and Foundations (SBC 303) draws a clear line between two levels of protection for concrete below ground. The first is damp-proofing for footings, neck columns and grade beams in non-submerged soils. It blocks capillary moisture and soil salts. The second is hydrostatic waterproofing (tanking) for basements, elevator pits and foundations under groundwater pressure.

Bashaer Al Khair offers two levels of protection. For new projects under construction, we install external tanking on footings, grade beams, and retaining walls before backfilling. For existing buildings with active basement or elevator-pit seepage, we apply internal negative-pressure hydraulic and crystalline waterproofing.

What Bashaer Al Khair's Work Includes:

  • Cleaning concrete footings, neck columns and grade beams, cutting back tie wires, and repairing honeycombs with non-shrink mortar.
  • Applying foundation coatings made for the job. We use heavy-duty rubberized bitumen emulsions for footings and grade beams. For basements and retaining walls we use modified bitumen roll tanking with protection boards.
  • Treating active groundwater seepage inside existing basements and elevator pits using hydraulic plug mortars and negative-pressure crystalline or cementitious systems.

Engineering Scope Boundaries & Transparency

  • In new construction, the foundation waterproofing spec must match the site's Geotechnical Soil Report and the structural engineer's drawings.
  • Never dump backfill soil and rock straight against waterproofed basement walls. Install rigid protection boards first.
Approved Material Systems:

Reinforced Modified Bituminous Membranes, Rubberized Bitumen Emulsions, Crystalline Negative-Side Cementitious Systems and Protection Boards

Substructure & Foundation Elements We Waterproof

Our service covers all underground concrete elements in new builds and existing properties:

1. Footings, Neck Columns & Ground Grade Beams

Substrate Type: The concrete base of villas and apartment buildings, before backfilling and ground-floor blockwork.

Suitability Condition:Coating all buried concrete faces and the top face of grade beams (DPC under the first block course) to block salt attack and rising damp.

2. New Basement Raft Slabs, Retaining Walls and Elevator Pits

Substrate Type: Basements and elevator pits below ground that face side earth pressure and groundwater.

Suitability Condition:Full external tanking with polyester-reinforced modified bitumen membranes, waterstops at cold joints and rigid protection boards.

3. Leaking Basements and Elevator Pits (Repair from the Inside, Negative Side)

Substrate Type: Finished basements and elevator shafts where digging up the outside soil is no longer possible.

Suitability Condition:Internal negative-pressure repair using hydraulic water-plug mortars, joint injection and penetrating crystalline cementitious coatings.
Pre-Application Substrate Diagnostics

Checks Before Foundation or Basement Waterproofing

Our engineer checks three site-specific factors before choosing your foundation or basement waterproofing system:

1. Groundwater Depth and Soil Chemistry (Coastal Sabkha or Rock Cut)

Footings above the water table need damp-proofing against soil salts. A basement under Obhur groundwater needs full hydrostatic tanking.

Impact on System Selection:Shows whether you need rubberized bitumen emulsion, reinforced sheet tanking or crystalline waterproofing.

2. Concrete Surface Condition (Honeycombing, Formwork Wires and Cold Joints)

Sticking-out tie wires or unpatched honeycomb pockets puncture membranes during backfilling. They also expose rebar directly to soil chlorides.

Impact on System Selection:Cutting tie wires, packing honeycombs with non-shrink mortar, and forming 45° fillets where footings meet columns.

3. Checking Cold Joints and Tie-Rod Holes in Existing Basements

In leaking existing basements, 90% of groundwater seepage happens along the slab-to-wall cold joint and through unsealed tie-rod holes.

Impact on System Selection:Routing the cold joint into a U-chase and packing it with hydraulic plug mortar before applying crystalline slurry.
Service-Specific Material & Assembly Comparison

Comparison of Foundation & Basement Waterproofing Systems

We match the waterproofing system to the structural element and the direction of water pressure:

Underground Damp-Proofing and Anti-Salt Barrier for Footings and Grade Beams

Polymer-Modified Rubberized Bituminous Emulsions / Liquid Coatings

Best Suited For: Coating concrete footings, column necks and grade beams in new construction to block capillary moisture and soil sulfates and chlorides.

Limitations & Engineering Precautions:Applied in several coats over prepared concrete. It does not replace reinforced sheet tanking on submerged basements.
Outside Waterproofing for New Basements and Retaining Walls

Polyester-Reinforced Modified Bituminous Membranes + Rigid Protection Boards

Best Suited For: Tanking under basement raft slabs (over blinding concrete) and along outer retaining walls before backfilling.

Limitations & Engineering Precautions:It must be shielded with a protection screed on horizontal blinding slabs and rigid protection boards on vertical walls before backfilling.
Capillary-Crystalline & Negative-Pressure Structural Barrier

Penetrating Crystalline & Negative-Side Hydraulic Cementitious Waterproofing

Best Suited For: Stopping inward groundwater seepage inside existing basements and elevator pits where outside excavation is impossible.

Limitations & Engineering Precautions:Needs grinding down to bare open-pore concrete and pre-soaking with water. This lets crystals grow deep inside the concrete capillaries.
Step-by-Step Application & Quality Control

Step-by-Step Engineering Workflow for Foundation & Basement Waterproofing

Safety Note: Deep foundation and retaining wall digs need safe trench shoring and ventilation. Do not backfill until the membrane inspection and protection boards are done.

1. Concrete Preparation, Tie-Wire Trimming & Honeycomb Repair

Cleaning concrete faces and cutting formwork tie wires below the surface. We patch honeycombs and tie holes with non-shrink mortar. We form 45° fillets where footings meet necks.

Quality Checkpoint: Smooth, continuous concrete surface with no sharp projections or open voids.

2. Applying Penetrating Primer (or Pre-Wetting for Crystalline Systems)

Applying penetrating bitumen primer for roll and emulsion systems. For internal crystalline systems, we pre-wet bare concrete with water.

Quality Checkpoint: Full primer penetration across all vertical and horizontal concrete faces.

3. Installing the Waterproofing and Sealing Cold Joints and DPC

Applying several coats of rubberized bitumen over footings and the top of grade beams (DPC). Or torch-welding reinforced bitumen rolls across basement walls.

Quality Checkpoint: 100% pinhole-free coverage and fully fused seam overlaps.

4. Installing Rigid Protection Boards Before Soil Backfilling

Fixing rigid protection boards or dimpled drainage sheets over waterproofed basement walls. Sharp backfill stones then cannot puncture the membrane when the soil is compacted.

Quality Checkpoint: Full mechanical protection checked before the trench is released for backfilling.

3 Key Substructure Details That Must Be Done Right

Long-term foundation and basement protection depends on detailing these three zones properly:

1. Basement Floor-to-Wall Construction Cold Joint

Failure Risk:Basement walls are poured after the raft slab. So this flat construction joint is the #1 way in for groundwater.

Our Engineering Treatment:In new builds, we embed PVC or hydrophilic waterstops plus exterior reinforcing strips. In existing basements, we cut out the joint and pack it with hydraulic mortar and crystalline waterproofing.

2. Top of Ground Grade Beams Under Masonry Walls (DPC)

Failure Risk:Coating only the sides of a grade beam and leaving its top bare lets soil moisture wick straight up into ground-floor block walls.

Our Engineering Treatment:Installing a continuous horizontal damp-proof barrier across the top of all grade beams before the first course of masonry.

3. The Sunken Elevator Pit Below the Basement Slab

Failure Risk:The elevator pit sits 1.5–2 meters below the main basement slab. So it takes the highest groundwater pressure.

Our Engineering Treatment:Double-layer outer membrane tanking during construction. For existing pits, inside hydraulic plugging and crystalline lining.

Critical Mistakes & Prohibitions in Foundation Waterproofing

We warn owners and builders in Jeddah and Makkah against these damaging shortcuts:

Never backfill rocky soil straight against basement waterproofing membranes without rigid protection boards.
Never brush bitumen straight over honeycombed concrete or protruding tie wires. Repair them with mortar first.
Never rely on a thin cold-applied damp-proofing paint for a submerged basement in districts with a high water table.
How to Choose: Waterproofing, Plumbing Repair or Leak Detection

New Foundation Tanking, Existing Basement Repair and Leak Detection

Choose the right path, depending on whether your building is under construction or already in use:

Underground Pipe Leak Detection Around Foundations & Basements
Pre-backfill preventive substructure protection (SBC 303)

New villa or apartment building under construction, after pouring footings, grade beams or basement walls

Correct Engineering Action: Carry out outside foundation damp-proofing and basement sheet tanking with protection boards before backfilling.

When Waterproofing Applies: The best and most cost-effective stage to protect the building substructure for good.
Negative hydrostatic groundwater pressure on buried walls

Existing basement or elevator pit with groundwater seeping in through walls or floor joints

Correct Engineering Action: Carry out inside negative-side hydraulic plugging and penetrating crystalline waterproofing.

When Waterproofing Applies: Strong inside waterproofing of the structure without digging around the finished building.
Adjacent underground plumbing rupture or leaking cistern

Sudden water in a basement or courtyard from a burst underground supply pipe or a leaking tank

Correct Engineering Action: Run Underground Pipe or Tank Leak Detection to stop the active water source first. Then seal the basement wall.

When Waterproofing Applies: Applied after stopping the external plumbing leak.
Local Climate, Soil & Architectural Context in Makkah

Why Basement and Foundation Waterproofing in Makkah Needs Local Expertise

Property in Jeddah? View Jeddah Page

In Makkah, many homes and villas are built on rock-cut hillside plots. They need deep concrete retaining walls and basements. Seasonal rainwater travels through rock cracks and builds water pressure behind retaining walls and footings.

Makkah has intense heat radiation, made stronger by the rocky mountain basins around it. Seasonal torrential rain also loads flat roofs fast and sends runoff along rock fissures toward foundations and underground cisterns. Multi-story homes and hotels in Makkah also have dense rooftop equipment, which creates critical penetration zones.

Key Building Envelope Challenges We Solve in Makkah:

  • Groundwater and rainwater moving through rock cracks behind retaining walls in Al-Awali, Al-Shara’i and sloped districts.
  • Sharp crushed-rock backfill in Makkah excavations makes rigid protection boards a must over retaining wall membranes.

Common Local Application Scenarios in Makkah:

Foundation, Retaining Wall and Basement Waterproofing in Al-Awali, Al-Shara’i, Batha Quraish and Al-Zaydi

Applying footing and grade-beam coatings. We also fit reinforced bitumen roll tanking with protection boards on rock-cut retaining walls.

Serving all Makkah districts and subdivisions: Al-Awali, Al-Shara’i, Batha Quraish, Al-Zaydi, Al-Shawqiyah, Al-Kakiyah, Wali Al-Ahd, Al-Umrah and Al-Nawariyah.All Waterproofing Services in Makkah

Factors Determining Foundation & Basement Waterproofing Cost

Foundation and basement waterproofing quotes in Jeddah and Makkah are based on:

1. Structural Parts and Total Surface Area (Footings and Beams or Full Basement)

Calculated from the real unfolded concrete area of footings, necks, grade beams, or basement raft and retaining walls.

Inspection Requirement: Reviewing structural drawings or taking measurements on site.

2. Protection Level (Damp-Proof Coating or Reinforced Sheet Tanking with Protection Boards)

Single- or double-ply reinforced bituminous roll tanking with rigid protection boards costs differently from liquid emulsion damp-proofing.

Inspection Requirement: Matching the spec to the water table depth and consultant requirements.

3. New Work Before Backfill or Inside Repair of an Existing Basement

Internal negative-pressure repair in existing basements means stripping plaster, plugging active leaks and applying crystalline mortars.

Inspection Requirement: On-site inspection of the basement or excavation.

Site Preparation Checklist Before Foundation / Basement Waterproofing

  • Fully strip timber formwork from footings, neck columns, grade beams or basement walls, and clear the trench.
  • On high-water-table sites in Jeddah, keep dewatering pumps running so concrete stays dry while the membrane is installed.
  • Hold all soil backfilling until the waterproofing has cured and been checked, and protection boards are fitted.

Quality Check Before Releasing Foundations for Backfilling

Foundations stay buried for decades. So we check them carefully before backfill:

100% Visual & Seam Continuity Inspection Across All Faces

Checking every footing face, column neck and grade-beam top, and probing all basement membrane seams.

Protection Board Coverage Verification Before Backfilling

Checked across all membrane-waterproofed retaining and basement walls before soil is placed.

Technical Standards & 6-Step Field Evaluation Protocol
SBC 602

Saudi Building Code: Energy Conservation for Low-Rise Residential Buildings (SBC 602)

Sets the maximum heat transfer (U-value) for roofs and outer walls in low-rise villas, by climate zone. Jeddah and Makkah are hot zones that need strong roof heat resistance.

SBC 601

Saudi Building Code: Energy Conservation for Non-Residential Buildings (SBC 601)

Sets the thermal performance of building envelopes for commercial, office, hotel and multi-story buildings. It stresses continuous insulation and fewer thermal bridges.

SBC 303

Saudi Building Code: Soils and Foundations, Damp-Proofing and Waterproofing (SBC 303)

Separates damp-proofing (no water pressure) from full waterproofing. Full waterproofing is needed where groundwater, water pressure, or sulfate and chloride soils are present, as in coastal Jeddah.

TDS / SDS & Potable Water Standards

Manufacturer Technical Data Sheets (TDS), Safety Data Sheets (SDS) and Potable Contact Certifications

Manufacturer TDS documents set the maximum base moisture, primer pairing, use rate per m², recoat intervals and full curing times before water immersion.

01. Confirming There Are No Active Plumbing Leaks Before Waterproofing

Before we propose waterproofing for roofs, bathrooms, tanks or pools, we check whether the moisture comes from pressurized pipes, drains or float valves. If it does, we start with leak detection.

02. Inspecting Substrate Condition & Existing Layers

We check the substrate type (concrete, tile, metal), screed condition, cracks, honeycombing and hollow tiles. We also check whether existing insulation can be restored or must be removed.

03. Measuring Trapped Moisture & Checking Drainage Slopes

We map ponding zones, slope toward rainwater scuppers and drains, and moisture levels under tiles or inside the concrete. This prevents blistering after application.

04. Matching Waterproofing / Thermal System to Usage & Exposure

We determine whether the asset requires waterproofing, thermal insulation, or a combined system, selecting materials matched to foot traffic, UV exposure, or continuous water immersion.

05. Detailing Critical Zones (Upstands, Expansion Joints & Penetrations)

We specify details for parapet wall coving and upstands, structural expansion joints, HVAC and tank plinths, floor drains and pipe sleeves.

06. Defining Work Scope & Transparent Quotation Breakdown

We give a clear scope covering surface preparation, the proposed system layers, and topcoat or protection needs. This way the client understands exactly what the quote covers.

Engineering Scope & Quotation Request Engine

Build Your Project Scope & Request an Itemized Quote in Makkah

We never quote vague flat rates without checking your surface. Choose your project details below to get a technical scope summary and book an engineer visit.

Itemized Engineering Quote ScopeMakkah
Target System: SBS/HDPE Foundation Membranes, Crystalline Waterproofing & Negative-Side Hydrostatic Barriers
Surface Prep Line Item: Mechanical grinding, crack/honeycomb repair, 45° coving, and compatible primer coat.
Critical Details & Protection: Sealing drains, expansion joints, and pipe penetrations, and checking the topcoat and protection.
Ready-to-Send Scope Summary:
Hello Bashaer Al Khair, I would like to request an inspection and quotation for waterproofing/insulation:
- Service: Basement & Foundation Waterproofing Makkah
- City: Makkah
- Property Type: Residential Villa
- Approx. Area: 100 to 250 m² (Standard Villa Roof/Tank)
- Substrate State: New Concrete / Screed Ready for Insulation
Interactive Smart Insulation & Waterproofing Finder

Choose Your Property Details for an Instant Expert Tip

Recommended Waterproofing / Insulation Service in Makkah:

Complete Roof Waterproofing (Concrete & Tiled Roofs)

Proposed Engineering Assembly: Reinforced Liquid Polyurethane Membranes or Bitumen Systems Matched to the Deck

Gives full roof rainwater protection. We detail the slope, parapet coving and drain collars.

Interactive Waterproofing & Insulation System Guide

Material and System Comparison: Where Each System Works Best and Its Limits

Filter by building zone to compare each system on water exposure, sun UV resistance, foot traffic, protective layers, and surface limits:

Sheet Membrane Waterproofing

Modified Bituminous Membranes (APP / SBS Rolls)

Primary Use Cases & Compatible Substrates:

Concrete roofs before tiling, buried foundations, retaining walls, and exposed roofs with no traffic (with mineral slate-surfaced APP rolls).

Substrates: Smooth reinforced concrete slabs and cured slope screed. Prime them with a matching bitumen primer.

Water Exposure Rating:

Strong against rainwater ponding and damp in the ground. The side (10 cm) and end (15 cm) laps must be fully fused.

Solar & UV Resistance:

Smooth rolls need UV cover. Mineral-slate-surfaced APP membranes resist direct sun on roofs with no traffic.

Foot Traffic Suitability:

Low when exposed. It needs a geotextile separation felt and a protective screed or tiling for regular foot traffic.

Protective Layer Needed:

Yes, on roofs with traffic and buried foundations. Use protection boards or non-woven geotextile felt under the screed or backfill.

Technical Limitations & Precautions:

Not suitable for drinking water tanks inside buildings or swimming pools. Seam quality depends on skilled lap work.

Grinding sharp concrete projections, forming 45° cementitious cant strips at wall junctions, and applying bituminous primer.View Service Page
Two-Component Slurry Waterproofing

Polymer-Modified Flexible Cementitious Waterproofing

Primary Use Cases & Compatible Substrates:

Bathrooms and wet zones before tiling, concrete water tanks, swimming pool shells under mosaic tiles, and foundations.

Substrates: Sound reinforced concrete, cement renders, and plastered masonry. The surface must be saturated-surface-dry (SSD).

Water Exposure Rating:

Made for constant water contact (tanks and pools). It handles positive and some negative water pressure.

Solar & UV Resistance:

Moderate to low under long direct desert sun. Cover it with ceramic or mosaic tiles or protective coatings.

Foot Traffic Suitability:

Handles light foot traffic during work once cured. Permanent foot traffic needs protective tiling or screed.

Protective Layer Needed:

Yes, on floors and decks. Use ceramic or porcelain tiles with a matching C2TE/S1 flexible adhesive, or a protective screed.

Technical Limitations & Precautions:

Bridges cracks less than pure polyurethane membranes. Not meant as an exposed roof coating over wide thermal joints.

Remove laitance and form oils. Repair honeycombing with non-shrink mortar. Pre-wet the surface with no standing water.View Service Page
Seamless Liquid-Applied Waterproofing

Liquid-Applied Acrylic & Hybrid Elastomeric Membranes

Primary Use Cases & Compatible Substrates:

Sloped exposed roofs without heavy ponding, UV topcoat over spray polyurethane foam, and parapet and roof repair.

Substrates: Concrete, cement screed, closed-cell spray polyurethane foam (SPF), and tiled surfaces that are properly abraded and primed.

Water Exposure Rating:

Works well against running rainwater. Pure acrylics are not advised for permanent ponding unless they are PU-hybrid.

Solar & UV Resistance:

Excellent. It resists UV damage and keeps its stretch and its white or light, sun-reflecting finish.

Foot Traffic Suitability:

Suits light maintenance foot traffic. Regular traffic needs full fleece reinforcement or a pedestrian-grade PU topcoat.

Protective Layer Needed:

No UV cover needed. The membrane is made for direct sun.

Technical Limitations & Precautions:

Not suitable for tanks or pools full of water. It cannot fix severe negative roof slopes that hold deep water.

Clean well, dry the surface, seal hairline cracks, and apply a primer matched to the surface pores.View Service Page
High-Elongation Seamless Polyurethane Membrane

High-Elastomeric Liquid Polyurethane Waterproofing Systems

Primary Use Cases & Compatible Substrates:

Concrete and tiled roofs with ponding water, balconies, terraces, and rooftop equipment areas.

Substrates: Dry concrete (<4–5% moisture content), and existing ceramic/porcelain tiles after mechanical grinding and specialized epoxy/PU primer.

Water Exposure Rating:

Very good against standing and ponding rainwater. It bridges cracks well through heat cycles.

Solar & UV Resistance:

Aromatic base coats need an aliphatic polyurethane UV-stable topcoat when left in direct sun.

Foot Traffic Suitability:

Good to high durability with a pedestrian-grade aliphatic polyurethane wear coat.

Protective Layer Needed:

Needs an aliphatic UV topcoat if exposed. If tiled over, use silica sand or a geotextile layer.

Technical Limitations & Precautions:

It can peel or blister over old tiles whose sand bed is full of trapped water.

Moisture testing, surface profiling, polyurethane joint sealant detailing, and a matching primer coat.View Service Page
Building Envelope Thermal Insulation (SBC 601 / 602 Context)

Rigid Thermal Insulation Boards (XPS / EPS / PIR)

Primary Use Cases & Compatible Substrates:

Villa, home, and commercial flat roofs (inverted or standard roof builds) to cut heat transfer.

Substrates: Fitted over tested waterproofing membranes (in inverted roofs with geotextile filter fabric) under ballast or tiles.

Water Exposure Rating:

Extruded polystyrene (XPS) boards absorb little water. But board joints are NOT waterproof, so a separate waterproofing membrane is a must.

Solar & UV Resistance:

It breaks down under direct UV and wind lift. Always cover it with geotextile fabric and gravel ballast, tiles, or screed.

Foot Traffic Suitability:

Takes foot traffic once covered by a load-spreading screed or paving slabs matched to the board strength.

Protective Layer Needed:

Required: a non-woven geotextile filter layer plus heavy ballast, paving tiles, or screed. This stops UV damage and wind lift.

Technical Limitations & Precautions:

It never stops water leaks by itself. It only adds heat resistance to a multi-layer roof system.

First flood-test and check the waterproofing membrane below. Make sure the bed is flat and free of debris.View Service Page
Seamless Heat and Moisture Barrier System (Needs UV Topcoat)

Closed-Cell Spray Polyurethane Foam (SPF System)

Primary Use Cases & Compatible Substrates:

Exposed concrete roofs, corrugated metal and warehouse roofs, and roofs with many HVAC or pipe penetrations that need seamless cover.

Substrates: Dry, clean concrete decks, primed and rust-free metal decks, and solid surfaces free of moisture, oil, and loose dust.

Water Exposure Rating:

Closed-cell SPF with a continuous elastomeric or acrylic topcoat resists rainwater well when the roof drains properly.

Solar & UV Resistance:

Raw polyurethane foam oxidizes and chalks fast under UV rays. A UV-resistant elastomeric topcoat is a must.

Foot Traffic Suitability:

Moderate. It handles careful maintenance traffic. Sharp tools or dragged heavy equipment can puncture the topcoat.

Protective Layer Needed:

Required: a UV-protective elastomeric acrylic or polyurethane coating, or geotextile separation felt under screed or tiles.

Technical Limitations & Precautions:

Open-cell foam is not suitable for outdoor roofs. Any gap in the UV topcoat exposes the foam to sun damage.

Pressure wash and dry fully. Remove loose mortar. Mask nearby AC units, solar panels, and parapets.View Service Page
Continuous-Immersion Waterproofing & Concrete Lining

Special Water Tank and Pool Coatings (Epoxy and Hydraulic Mortars)

Primary Use Cases & Compatible Substrates:

Inside lining of reinforced concrete water tanks (using certified drinking-water systems) and swimming pool shells.

Substrates: Reinforced concrete that is mechanically profiled. Seal all honeycombing, tie-rod holes, and active negative leaks first.

Water Exposure Rating:

Made for 24/7 constant water contact. It resists chlorides and water treatment chemicals.

Solar & UV Resistance:

Tank epoxies suit enclosed tanks (low UV stability). Outdoor pools use flexible cement membranes under tiles.

Foot Traffic Suitability:

High abrasion resistance during regular tank cleaning once the full curing time from the maker is done.

Protective Layer Needed:

Drinking-water tank epoxy is the final smooth lining. Pool cement waterproofing is covered by mosaic tiles and chemical-resistant grout.

Technical Limitations & Precautions:

Never assume general industrial epoxy is safe for drinking water. Ask for proof of drinking-water compliance and allow full cure time.

Ventilate the tank. Grind off concrete laitance. Rout and plug cracks with hydraulic mortar. Form corner fillets. Dry the surface.View Service Page

Important Engineering Note: This guide compares material families. The final system, primer pairing, and layer build-up are set after an on-site surface and moisture check per the maker TDS.

FAQs — Basement and Foundation Waterproofing Makkah

Technical Answers on Basement and Foundation Waterproofing in Makkah

What is the difference between footing damp-proofing and basement waterproofing under SBC 303?

Under SBC 303 principles, footings and grade beams above the water table get damp-proofing. This stops capillary moisture and soil salts. Basements, elevator pits and submerged structures need full hydrostatic waterproofing (tanking) built to resist constant water pressure.

Why must the top of the ground grade beam be waterproofed before laying block walls?

If only the sides of a grade beam are coated and the top is left bare, damp wicks up into the first course of ground-floor blockwork. This causes peeling paint above skirting boards. Coating the top of the grade beam acts as a horizontal Damp-Proof Course (DPC).

Can an existing leaking basement or elevator pit be waterproofed from the inside without digging outside?

Yes. Where outside digging is impossible on finished buildings, we apply internal negative-side waterproofing. We strip plaster down to bare concrete and plug active weeps with fast-setting hydraulic mortar. Then we apply penetrating crystalline cement coatings that seal concrete pores against inward water pressure.

What is the purpose of installing protection boards over basement wall waterproofing?

During backfilling and compaction, sharp stones press hard on underground walls. Rigid protection boards shield the waterproofing membrane from punctures and scrapes.

Engineering Guides, Symptom Diagnosis & Material Comparisons

Comparison Guides to Help You Decide

Browse All 12 Engineering Guides
Moisture Symptom Diagnostic Guide11 min

Lower Wall Dampness and Peeling Paint Causes: How to Tell Plumbing Leaks from Rising Damp

Paint blisters or white salt crystals 15 to 60 cm above the skirting boards are never just a cosmetic issue to repaint. They show active moisture movement that must be traced to its source.

Read Engineering Guide & Comparison
Bathroom Ceiling Leak Diagnostic Guide11 min

Water Leaking from the Bathroom Ceiling: How to Find the Exact Source Upstairs Without Random Demolition

Yellow stains or active drops may appear on your bathroom ceiling or gypsum soffit. The source is in the wet area directly above. But is it a pressurized supply pipe, a drainage elbow, worn tile grout or a breached slab membrane?

Read Engineering Guide & Comparison
High Water Bill Diagnostic Guide12 min

Sudden High Water Bill in Jeddah and Makkah: Step-by-Step Guide to Checking the Meter, Float Valve and Underground Tank

Your monthly water bill may double or triple with no change in household size and no visible dampness indoors. Then water is almost certainly escaping silently underground or straight into a drain line. Here is how to find the culprit step by step.

Read Engineering Guide & Comparison
Pool Water Loss Diagnostic Guide11 min

Swimming Pool Water Level Drop in Jeddah and Makkah: How to Tell Evaporation from Plumbing and Shell Leaks

Every outdoor pool loses water to evaporation in the heat of Jeddah and Makkah. But when does daily loss point to a real leak in a skimmer, light conduit, filter pipe or the shell?

Read Engineering Guide & Comparison
CallWhatsApp