Basement and Foundation Waterproofing in Makkah: Protecting Retaining Walls, Grade Beams and Basements
In Makkah, we waterproof footings, grade beams, rock-cut retaining walls and building basements. We guard against trapped groundwater in rock cracks and soil dampness. Protection boards go on before backfilling.

Why Waterproofing Below Ground Is the First Defense for a Long-Lasting Building
Concrete below ground (footings, neck columns, grade beams, raft slabs and basement walls) is porous and soaks up soil moisture. Groundwater often carries dissolved chlorides and sulfates. In Jeddah and Makkah, salty groundwater can enter unprotected concrete. Sulfates attack the cement, and chlorides corrode the reinforcing steel. This causes cracks and spalling.
Unsealed grade beams and foundation necks also let soil moisture creep upward into ground-floor walls. This causes paint blistering and salt deposits above the skirting boards. In basements, unsealed retaining walls cause active seepage, flooded floors and mold.
Chronic Rising Damp, Salt Deposits and Peeling Paint Along Ground-Floor Walls
Technical Mechanism: Salty soil moisture wicks upward through unsealed foundation necks and grade beams into ground-floor blockwork.
Groundwater Seepage in Basement Retaining Walls, Floor Slabs or Elevator Pits
Technical Mechanism: Groundwater pressure from outside pushes water in through unsealed cold joints, tie-rod holes or outer membranes damaged during backfill.
Corrosion of Foundation Neck Rebar and Spalling of Underground Concrete Cover
Technical Mechanism: Applying a thin, diluted coat of cheap bitumen over rough, honeycombed concrete. There is no mortar smoothing and no protection boards before backfilling.
Protecting Footings, Grade Beams and Basements from Groundwater and Salts in Makkah
For Footings, Neck Columns and Grade Beams Above the Water Table
Repairing honeycombs, trimming tie wires, and coating all buried faces and the top of grade beams (DPC) with rubberized bitumen. This blocks soil salts and rising damp.
For Basements, Elevator Pits and Retaining Walls Under Water Pressure
Outer reinforced bitumen membrane tanking with waterstops and protection boards for new builds. For existing basements, inside crystalline waterproofing.
Illustrative diagram only. The actual layer order and spec are set after an on-site surface inspection, per manufacturer TDS.
Technical Definition & SBC 303 Principles for Substructure Protection
The Saudi Building Code for Soils and Foundations (SBC 303) draws a clear line between two levels of protection for concrete below ground. The first is damp-proofing for footings, neck columns and grade beams in non-submerged soils. It blocks capillary moisture and soil salts. The second is hydrostatic waterproofing (tanking) for basements, elevator pits and foundations under groundwater pressure.
Bashaer Al Khair offers two levels of protection. For new projects under construction, we install external tanking on footings, grade beams, and retaining walls before backfilling. For existing buildings with active basement or elevator-pit seepage, we apply internal negative-pressure hydraulic and crystalline waterproofing.
What Bashaer Al Khair's Work Includes:
- Cleaning concrete footings, neck columns and grade beams, cutting back tie wires, and repairing honeycombs with non-shrink mortar.
- Applying foundation coatings made for the job. We use heavy-duty rubberized bitumen emulsions for footings and grade beams. For basements and retaining walls we use modified bitumen roll tanking with protection boards.
- Treating active groundwater seepage inside existing basements and elevator pits using hydraulic plug mortars and negative-pressure crystalline or cementitious systems.
Engineering Scope Boundaries & Transparency
- In new construction, the foundation waterproofing spec must match the site's Geotechnical Soil Report and the structural engineer's drawings.
- Never dump backfill soil and rock straight against waterproofed basement walls. Install rigid protection boards first.
Reinforced Modified Bituminous Membranes, Rubberized Bitumen Emulsions, Crystalline Negative-Side Cementitious Systems and Protection Boards
Substructure & Foundation Elements We Waterproof
Our service covers all underground concrete elements in new builds and existing properties:
1. Footings, Neck Columns & Ground Grade Beams
Substrate Type: The concrete base of villas and apartment buildings, before backfilling and ground-floor blockwork.
2. New Basement Raft Slabs, Retaining Walls and Elevator Pits
Substrate Type: Basements and elevator pits below ground that face side earth pressure and groundwater.
3. Leaking Basements and Elevator Pits (Repair from the Inside, Negative Side)
Substrate Type: Finished basements and elevator shafts where digging up the outside soil is no longer possible.
Checks Before Foundation or Basement Waterproofing
Our engineer checks three site-specific factors before choosing your foundation or basement waterproofing system:
1. Groundwater Depth and Soil Chemistry (Coastal Sabkha or Rock Cut)
Footings above the water table need damp-proofing against soil salts. A basement under Obhur groundwater needs full hydrostatic tanking.
2. Concrete Surface Condition (Honeycombing, Formwork Wires and Cold Joints)
Sticking-out tie wires or unpatched honeycomb pockets puncture membranes during backfilling. They also expose rebar directly to soil chlorides.
3. Checking Cold Joints and Tie-Rod Holes in Existing Basements
In leaking existing basements, 90% of groundwater seepage happens along the slab-to-wall cold joint and through unsealed tie-rod holes.
Comparison of Foundation & Basement Waterproofing Systems
We match the waterproofing system to the structural element and the direction of water pressure:
Polymer-Modified Rubberized Bituminous Emulsions / Liquid Coatings
Best Suited For: Coating concrete footings, column necks and grade beams in new construction to block capillary moisture and soil sulfates and chlorides.
Polyester-Reinforced Modified Bituminous Membranes + Rigid Protection Boards
Best Suited For: Tanking under basement raft slabs (over blinding concrete) and along outer retaining walls before backfilling.
Penetrating Crystalline & Negative-Side Hydraulic Cementitious Waterproofing
Best Suited For: Stopping inward groundwater seepage inside existing basements and elevator pits where outside excavation is impossible.
Step-by-Step Engineering Workflow for Foundation & Basement Waterproofing
1. Concrete Preparation, Tie-Wire Trimming & Honeycomb Repair
Cleaning concrete faces and cutting formwork tie wires below the surface. We patch honeycombs and tie holes with non-shrink mortar. We form 45° fillets where footings meet necks.
2. Applying Penetrating Primer (or Pre-Wetting for Crystalline Systems)
Applying penetrating bitumen primer for roll and emulsion systems. For internal crystalline systems, we pre-wet bare concrete with water.
3. Installing the Waterproofing and Sealing Cold Joints and DPC
Applying several coats of rubberized bitumen over footings and the top of grade beams (DPC). Or torch-welding reinforced bitumen rolls across basement walls.
4. Installing Rigid Protection Boards Before Soil Backfilling
Fixing rigid protection boards or dimpled drainage sheets over waterproofed basement walls. Sharp backfill stones then cannot puncture the membrane when the soil is compacted.
3 Key Substructure Details That Must Be Done Right
Long-term foundation and basement protection depends on detailing these three zones properly:
1. Basement Floor-to-Wall Construction Cold Joint
Failure Risk:Basement walls are poured after the raft slab. So this flat construction joint is the #1 way in for groundwater.
2. Top of Ground Grade Beams Under Masonry Walls (DPC)
Failure Risk:Coating only the sides of a grade beam and leaving its top bare lets soil moisture wick straight up into ground-floor block walls.
3. The Sunken Elevator Pit Below the Basement Slab
Failure Risk:The elevator pit sits 1.5–2 meters below the main basement slab. So it takes the highest groundwater pressure.
Critical Mistakes & Prohibitions in Foundation Waterproofing
We warn owners and builders in Jeddah and Makkah against these damaging shortcuts:
New Foundation Tanking, Existing Basement Repair and Leak Detection
Choose the right path, depending on whether your building is under construction or already in use:
New villa or apartment building under construction, after pouring footings, grade beams or basement walls
Correct Engineering Action: Carry out outside foundation damp-proofing and basement sheet tanking with protection boards before backfilling.
Existing basement or elevator pit with groundwater seeping in through walls or floor joints
Correct Engineering Action: Carry out inside negative-side hydraulic plugging and penetrating crystalline waterproofing.
Sudden water in a basement or courtyard from a burst underground supply pipe or a leaking tank
Correct Engineering Action: Run Underground Pipe or Tank Leak Detection to stop the active water source first. Then seal the basement wall.
Why Basement and Foundation Waterproofing in Makkah Needs Local Expertise
In Makkah, many homes and villas are built on rock-cut hillside plots. They need deep concrete retaining walls and basements. Seasonal rainwater travels through rock cracks and builds water pressure behind retaining walls and footings.
Makkah has intense heat radiation, made stronger by the rocky mountain basins around it. Seasonal torrential rain also loads flat roofs fast and sends runoff along rock fissures toward foundations and underground cisterns. Multi-story homes and hotels in Makkah also have dense rooftop equipment, which creates critical penetration zones.
Key Building Envelope Challenges We Solve in Makkah:
- Groundwater and rainwater moving through rock cracks behind retaining walls in Al-Awali, Al-Shara’i and sloped districts.
- Sharp crushed-rock backfill in Makkah excavations makes rigid protection boards a must over retaining wall membranes.
Common Local Application Scenarios in Makkah:
Applying footing and grade-beam coatings. We also fit reinforced bitumen roll tanking with protection boards on rock-cut retaining walls.
Factors Determining Foundation & Basement Waterproofing Cost
Foundation and basement waterproofing quotes in Jeddah and Makkah are based on:
1. Structural Parts and Total Surface Area (Footings and Beams or Full Basement)
Calculated from the real unfolded concrete area of footings, necks, grade beams, or basement raft and retaining walls.
2. Protection Level (Damp-Proof Coating or Reinforced Sheet Tanking with Protection Boards)
Single- or double-ply reinforced bituminous roll tanking with rigid protection boards costs differently from liquid emulsion damp-proofing.
3. New Work Before Backfill or Inside Repair of an Existing Basement
Internal negative-pressure repair in existing basements means stripping plaster, plugging active leaks and applying crystalline mortars.
Site Preparation Checklist Before Foundation / Basement Waterproofing
- Fully strip timber formwork from footings, neck columns, grade beams or basement walls, and clear the trench.
- On high-water-table sites in Jeddah, keep dewatering pumps running so concrete stays dry while the membrane is installed.
- Hold all soil backfilling until the waterproofing has cured and been checked, and protection boards are fitted.
Quality Check Before Releasing Foundations for Backfilling
Foundations stay buried for decades. So we check them carefully before backfill:
Checking every footing face, column neck and grade-beam top, and probing all basement membrane seams.
Checked across all membrane-waterproofed retaining and basement walls before soil is placed.
Saudi Building Code: Energy Conservation for Low-Rise Residential Buildings (SBC 602)
Sets the maximum heat transfer (U-value) for roofs and outer walls in low-rise villas, by climate zone. Jeddah and Makkah are hot zones that need strong roof heat resistance.
Saudi Building Code: Energy Conservation for Non-Residential Buildings (SBC 601)
Sets the thermal performance of building envelopes for commercial, office, hotel and multi-story buildings. It stresses continuous insulation and fewer thermal bridges.
Saudi Building Code: Soils and Foundations, Damp-Proofing and Waterproofing (SBC 303)
Separates damp-proofing (no water pressure) from full waterproofing. Full waterproofing is needed where groundwater, water pressure, or sulfate and chloride soils are present, as in coastal Jeddah.
Manufacturer Technical Data Sheets (TDS), Safety Data Sheets (SDS) and Potable Contact Certifications
Manufacturer TDS documents set the maximum base moisture, primer pairing, use rate per m², recoat intervals and full curing times before water immersion.
Before we propose waterproofing for roofs, bathrooms, tanks or pools, we check whether the moisture comes from pressurized pipes, drains or float valves. If it does, we start with leak detection.
We check the substrate type (concrete, tile, metal), screed condition, cracks, honeycombing and hollow tiles. We also check whether existing insulation can be restored or must be removed.
We map ponding zones, slope toward rainwater scuppers and drains, and moisture levels under tiles or inside the concrete. This prevents blistering after application.
We determine whether the asset requires waterproofing, thermal insulation, or a combined system, selecting materials matched to foot traffic, UV exposure, or continuous water immersion.
We specify details for parapet wall coving and upstands, structural expansion joints, HVAC and tank plinths, floor drains and pipe sleeves.
We give a clear scope covering surface preparation, the proposed system layers, and topcoat or protection needs. This way the client understands exactly what the quote covers.
Build Your Project Scope & Request an Itemized Quote in Makkah
We never quote vague flat rates without checking your surface. Choose your project details below to get a technical scope summary and book an engineer visit.
Choose Your Property Details for an Instant Expert Tip
Complete Roof Waterproofing (Concrete & Tiled Roofs)
Proposed Engineering Assembly: Reinforced Liquid Polyurethane Membranes or Bitumen Systems Matched to the Deck
Gives full roof rainwater protection. We detail the slope, parapet coving and drain collars.
Material and System Comparison: Where Each System Works Best and Its Limits
Filter by building zone to compare each system on water exposure, sun UV resistance, foot traffic, protective layers, and surface limits:
Modified Bituminous Membranes (APP / SBS Rolls)
Concrete roofs before tiling, buried foundations, retaining walls, and exposed roofs with no traffic (with mineral slate-surfaced APP rolls).
Substrates: Smooth reinforced concrete slabs and cured slope screed. Prime them with a matching bitumen primer.
Strong against rainwater ponding and damp in the ground. The side (10 cm) and end (15 cm) laps must be fully fused.
Smooth rolls need UV cover. Mineral-slate-surfaced APP membranes resist direct sun on roofs with no traffic.
Low when exposed. It needs a geotextile separation felt and a protective screed or tiling for regular foot traffic.
Yes, on roofs with traffic and buried foundations. Use protection boards or non-woven geotextile felt under the screed or backfill.
Not suitable for drinking water tanks inside buildings or swimming pools. Seam quality depends on skilled lap work.
Polymer-Modified Flexible Cementitious Waterproofing
Bathrooms and wet zones before tiling, concrete water tanks, swimming pool shells under mosaic tiles, and foundations.
Substrates: Sound reinforced concrete, cement renders, and plastered masonry. The surface must be saturated-surface-dry (SSD).
Made for constant water contact (tanks and pools). It handles positive and some negative water pressure.
Moderate to low under long direct desert sun. Cover it with ceramic or mosaic tiles or protective coatings.
Handles light foot traffic during work once cured. Permanent foot traffic needs protective tiling or screed.
Yes, on floors and decks. Use ceramic or porcelain tiles with a matching C2TE/S1 flexible adhesive, or a protective screed.
Bridges cracks less than pure polyurethane membranes. Not meant as an exposed roof coating over wide thermal joints.
Liquid-Applied Acrylic & Hybrid Elastomeric Membranes
Sloped exposed roofs without heavy ponding, UV topcoat over spray polyurethane foam, and parapet and roof repair.
Substrates: Concrete, cement screed, closed-cell spray polyurethane foam (SPF), and tiled surfaces that are properly abraded and primed.
Works well against running rainwater. Pure acrylics are not advised for permanent ponding unless they are PU-hybrid.
Excellent. It resists UV damage and keeps its stretch and its white or light, sun-reflecting finish.
Suits light maintenance foot traffic. Regular traffic needs full fleece reinforcement or a pedestrian-grade PU topcoat.
No UV cover needed. The membrane is made for direct sun.
Not suitable for tanks or pools full of water. It cannot fix severe negative roof slopes that hold deep water.
High-Elastomeric Liquid Polyurethane Waterproofing Systems
Concrete and tiled roofs with ponding water, balconies, terraces, and rooftop equipment areas.
Substrates: Dry concrete (<4–5% moisture content), and existing ceramic/porcelain tiles after mechanical grinding and specialized epoxy/PU primer.
Very good against standing and ponding rainwater. It bridges cracks well through heat cycles.
Aromatic base coats need an aliphatic polyurethane UV-stable topcoat when left in direct sun.
Good to high durability with a pedestrian-grade aliphatic polyurethane wear coat.
Needs an aliphatic UV topcoat if exposed. If tiled over, use silica sand or a geotextile layer.
It can peel or blister over old tiles whose sand bed is full of trapped water.
Rigid Thermal Insulation Boards (XPS / EPS / PIR)
Villa, home, and commercial flat roofs (inverted or standard roof builds) to cut heat transfer.
Substrates: Fitted over tested waterproofing membranes (in inverted roofs with geotextile filter fabric) under ballast or tiles.
Extruded polystyrene (XPS) boards absorb little water. But board joints are NOT waterproof, so a separate waterproofing membrane is a must.
It breaks down under direct UV and wind lift. Always cover it with geotextile fabric and gravel ballast, tiles, or screed.
Takes foot traffic once covered by a load-spreading screed or paving slabs matched to the board strength.
Required: a non-woven geotextile filter layer plus heavy ballast, paving tiles, or screed. This stops UV damage and wind lift.
It never stops water leaks by itself. It only adds heat resistance to a multi-layer roof system.
Closed-Cell Spray Polyurethane Foam (SPF System)
Exposed concrete roofs, corrugated metal and warehouse roofs, and roofs with many HVAC or pipe penetrations that need seamless cover.
Substrates: Dry, clean concrete decks, primed and rust-free metal decks, and solid surfaces free of moisture, oil, and loose dust.
Closed-cell SPF with a continuous elastomeric or acrylic topcoat resists rainwater well when the roof drains properly.
Raw polyurethane foam oxidizes and chalks fast under UV rays. A UV-resistant elastomeric topcoat is a must.
Moderate. It handles careful maintenance traffic. Sharp tools or dragged heavy equipment can puncture the topcoat.
Required: a UV-protective elastomeric acrylic or polyurethane coating, or geotextile separation felt under screed or tiles.
Open-cell foam is not suitable for outdoor roofs. Any gap in the UV topcoat exposes the foam to sun damage.
Special Water Tank and Pool Coatings (Epoxy and Hydraulic Mortars)
Inside lining of reinforced concrete water tanks (using certified drinking-water systems) and swimming pool shells.
Substrates: Reinforced concrete that is mechanically profiled. Seal all honeycombing, tie-rod holes, and active negative leaks first.
Made for 24/7 constant water contact. It resists chlorides and water treatment chemicals.
Tank epoxies suit enclosed tanks (low UV stability). Outdoor pools use flexible cement membranes under tiles.
High abrasion resistance during regular tank cleaning once the full curing time from the maker is done.
Drinking-water tank epoxy is the final smooth lining. Pool cement waterproofing is covered by mosaic tiles and chemical-resistant grout.
Never assume general industrial epoxy is safe for drinking water. Ask for proof of drinking-water compliance and allow full cure time.
Important Engineering Note: This guide compares material families. The final system, primer pairing, and layer build-up are set after an on-site surface and moisture check per the maker TDS.
Technical Answers on Basement and Foundation Waterproofing in Makkah
What is the difference between footing damp-proofing and basement waterproofing under SBC 303?
Under SBC 303 principles, footings and grade beams above the water table get damp-proofing. This stops capillary moisture and soil salts. Basements, elevator pits and submerged structures need full hydrostatic waterproofing (tanking) built to resist constant water pressure.
Why must the top of the ground grade beam be waterproofed before laying block walls?
If only the sides of a grade beam are coated and the top is left bare, damp wicks up into the first course of ground-floor blockwork. This causes peeling paint above skirting boards. Coating the top of the grade beam acts as a horizontal Damp-Proof Course (DPC).
Can an existing leaking basement or elevator pit be waterproofed from the inside without digging outside?
Yes. Where outside digging is impossible on finished buildings, we apply internal negative-side waterproofing. We strip plaster down to bare concrete and plug active weeps with fast-setting hydraulic mortar. Then we apply penetrating crystalline cement coatings that seal concrete pores against inward water pressure.
What is the purpose of installing protection boards over basement wall waterproofing?
During backfilling and compaction, sharp stones press hard on underground walls. Rigid protection boards shield the waterproofing membrane from punctures and scrapes.
Related Waterproofing & Insulation Services in Makkah
View All Makkah Waterproofing ServicesBituminous Membrane Waterproofing in Makkah: Heavy-Duty Sheet Membranes for Roofs and Substructures
Water Tank Waterproofing in Makkah: Protecting Underground and Overhead Concrete Tanks
Roof Waterproofing in Makkah: Protecting Villa and Building Roofs from Rain and Heat Stress
Waterproofing Repair and Restoration in Makkah: Maintaining and Renewing Existing Systems
Comparison Guides to Help You Decide
Lower Wall Dampness and Peeling Paint Causes: How to Tell Plumbing Leaks from Rising Damp
Paint blisters or white salt crystals 15 to 60 cm above the skirting boards are never just a cosmetic issue to repaint. They show active moisture movement that must be traced to its source.
Water Leaking from the Bathroom Ceiling: How to Find the Exact Source Upstairs Without Random Demolition
Yellow stains or active drops may appear on your bathroom ceiling or gypsum soffit. The source is in the wet area directly above. But is it a pressurized supply pipe, a drainage elbow, worn tile grout or a breached slab membrane?
Sudden High Water Bill in Jeddah and Makkah: Step-by-Step Guide to Checking the Meter, Float Valve and Underground Tank
Your monthly water bill may double or triple with no change in household size and no visible dampness indoors. Then water is almost certainly escaping silently underground or straight into a drain line. Here is how to find the culprit step by step.
Swimming Pool Water Level Drop in Jeddah and Makkah: How to Tell Evaporation from Plumbing and Shell Leaks
Every outdoor pool loses water to evaporation in the heat of Jeddah and Makkah. But when does daily loss point to a real leak in a skimmer, light conduit, filter pipe or the shell?